Questions tagged [power-supply-unit]
Questions related to power supply units, aka PSUs
173
questions
2
votes
1
answer
537
views
Replacement the UPS APC Smart-UPS SRT 10000 battery while it's powered on?
I have an APC Smart-UPS SRT 10000 and need to replace the battery.
Would something bad happen if I replace it while it's still plugged in and powered on?
Or do I need to shut down the servers and ...
0
votes
2
answers
411
views
If I hot swap a power supply to a larger wattage, will it damage the server?
I have a Dell Poweredge R720 server with 2x redundant 750 Watt power supplies. If I wanted to upgrade those to 1100 Watts without shutting down the server and go through the process of hot swapping ...
3
votes
1
answer
1k
views
Understanding ipmitool output for "Power Supply" (PSU)
This Ubuntu server has two PSUs, I just ran ipmitool and it reported as follows:
# ipmitool sdr type "Power Supply"
PMBPower1 | DFh | ok | 10.0 | 624 Watts
PMBPower2 | E4h | ...
0
votes
0
answers
245
views
Cisco UCS C220 M4 PSU Fault In Diagnostics
Hello fellow Sysadmins.
A C220 M4 with the latest recommended firmware I am working on displays the following fault messages on latest version diagnostics at Server Health:
PSU1 PSU1_PWRGD: Power ...
-1
votes
2
answers
541
views
What's the name of the component that allows a hot-swap power supply to slot-in and provides all the cables in a 1..4U server?
In contrast to consumer grade PSUs, server PSUs sometimes come without cables. From what I gather, these are usually of the redundant variety or so called "1+1" configuration. I wander if ...
1
vote
1
answer
194
views
Is there any Linux mechanism to emergency-flush filesystem buffers on power loss?
A common "gotcha" with computers can happen when power gets cut to the computer without warning. Because the system loses power suddenly, it doesn't have a chance to flush cached filesystem ...
0
votes
0
answers
1k
views
How to disable iDRAC status / alerts for absent PSU or input lost
I have a number of Dell PER740 servers running iDRAC 9 in a lab.
As they are in a lab, I only need/want/have capacity for one power supply connected to each server.
However, I cannot find a way to ...
-1
votes
1
answer
93
views
Is redundant power supply really redundant?
Apologize for my inexperience or if I am missing something important here...
Everyone kept talking about how good it is to have redundant power supply in servers, yet no one talks about a redundant ...
3
votes
0
answers
58
views
Preserving a mothballed system: soft shutdown, PSU off or unplugged entirely?
I've got a system that looks like it's going to be kept around "just in case" (virtualization has already been explored). Long ago I had another such system but when when it needed to be ...
-2
votes
2
answers
341
views
Power limit in a 2x1600W server
I have a server with two 1600W power supply units (a Gigabyte GS-R22PHL if that helps).
Should I assume the maximum rated power is 1600W, and that the second unit is for redundancy, or that the ...
0
votes
1
answer
79
views
Trying to convert a Dell T420 Single Drive to Redundant. Looking for validating my steps
I have a Dell T420 and read different ways to upgrade it to redundant PSU's.
Details
I saw on Dell's website a thread where a user asked how to upgrade to a redundant PSU versus the single 550psu. ...
1
vote
0
answers
85
views
Using (dual) ATS for dual PSU server?
There's two parts to my question:
Does it make sense to hook up a dual PSU server to an ATS to speed up failover to the secondary circuit?
If yes, does it make sense to use two separate ATSes to ...
0
votes
1
answer
1k
views
Required PSU Power for 12 HDD SATA 7200RPM (i have 20 A on my PSU peripheral channel)
I have a Tower server with today many hard drives and i would like to add hard drives for securing a raid group and also to extend storage capacity.
Hardware spec before adding everything else :
PSU :...
0
votes
1
answer
422
views
HP PROLIANT 1300w hstns-pa01 PSU orange/amber light
I bought an HP Server PSU (For mining) - HP PROLIANT 1300w (hstns-pa01) - I plugged it in and it was working perfectly for 12h and 20min, then the rig shut down ( because no power) but PSU fan was ...
1
vote
1
answer
947
views
Grounding of a server rack on wheels
I have a 42HE 19” server rack which houses a bunch of equipment (UPS, PDU, server, network, ...). It has wheels so it’s easy to move and it stands on a concrete floor.
The rack is out of metal and ...
1
vote
3
answers
848
views
How to power-up PSU from Proliant DL185 without mobo?
I have an old Proliant DL185 G5 server with a 447325-001 Power supply backplane. Two connectors seem to be interesting, one is what looks like an ATX-power connector and connecting green to GND spins ...
0
votes
1
answer
296
views
Dell T420: can I replace the original non-redundant power supply with two redundant ones?
A Dell T420 bought in 2015 was originally configured with the single 550W non-redundant power supply. Replacement parts are cheap these days, and I'd like to replace the single P/S with dual ...
0
votes
1
answer
458
views
Can I safely run a server with redundant power supplies off of a standard 15 amp outlet?
I purchased a used HP Proliant DL380p Gen 8 off eBay. It has dual redundant power supplies, both at 750 watts. Doing the math, I realize that if both PSUs are at peak load, they will pull 12.5 amps ...
-2
votes
1
answer
2k
views
how to turn on Server power supply Lite-ON model PS-2122-8L1 without server chassis [closed]
I wanted build 48v DC power from 4 12v power supply units. Eventually i got my hands on Lite-On PS-2122-8L1 server psu. But after getting it, i am still unable power it on with out chassis. i mean i ...
1
vote
1
answer
235
views
HP DL380 G7 Power Calculation
My current Config
HP DL380 G7
2x E5620 CPU (80 W each)
8x 16 GB 1000 MHZ DDR3 Ram
4x Sata SSD
Dual 460 W Power supply.
Can I replace cpu's with Dual X5675 (95 W each) ?
HP ...
1
vote
1
answer
605
views
Newbie to Supermicro redundant PSU
Until recently I have never had a redundant PSU or a rack server for that matter. So, I think maybe I did this wrong? I have a Supermicro FatTwin 6026TT-HDTRF (CSE-827HD-R1400B case) that comes with a ...
0
votes
1
answer
457
views
Server suddenly very sensitive to minor brown-outs
We have a number of SuperMicro RAID 10 boxes with redundant PSU, the same model and spec and use the same rackmount APC UPS. One has suddenly taken to rebooting if there is a minor brown-out.
...
0
votes
0
answers
209
views
Step up voltage converter in datacenter?
I am setting up a rack in the data center that only has 110V. It is redundant, so I thought I could take one from each leg and get 110V, but when I used a voltmeter last night they somehow are on the ...
0
votes
1
answer
6k
views
What does orange light on power supply mean?
I have an Intel® Server System P4000CP Family. Today I've discovered that one of power supply has green light, second power supply has orange light. What does it mean?
0
votes
1
answer
198
views
Rel-time monitoring on Redundant PSU's
we're using 3 HP DL380 Servers with redundant power supplies and vmware esxi hypervisor is installed. is there a way to determine the actual status of the power supplies in real-time? current voltage ...
0
votes
1
answer
539
views
Zippy/EMACS G1W2-5760V3V Power supply manual or pinout information
I now have two different sizes of emac's power supplies and both have 2 extra pairs of wires, Red and black as well as yellow and black. On the model above they both have 2pin push connectors with ...
1
vote
1
answer
63
views
Using one power supply for my SunFire x4100
Is there a risk on using just one power supply on this server?, I just found out that you can POST and run stuff with only one power supply (even tho I still get the LED errors) , I read the manual ...
6
votes
2
answers
966
views
At my wits end. What could cause my server to randomly hard reset? (Seems to be related to ZFS)
I have a server that I built years ago that has worked like a champ. But within the past few months it has started to become seriously unstable with no discernible pattern. I have been debugging it ...
-1
votes
1
answer
28
views
On boot, server pulls full load of both PSUs -- any way to limit this or mitigate load spike?
I have a giant 24u server (Supermicro 4U X9DRI-F w/ 2x Xeon E5-2680) with 2 1200w PSUs. However, I only have 4 drives in right now, and my actual power draw (under the most stressful loads) is likely ...
0
votes
2
answers
2k
views
What PSU form-factor do I need?
So I finally got my Fantec SRC-2080x07 2U server chassis replacement.
Only to find out that the Be Quiet TFX Power 2 300W Gold PSU that I ordered, is too small to fit.
Here's a picture of the PSU ...
0
votes
1
answer
353
views
Does it make sense to connect a redundant power supply to a C14 splitter?
Recently visiting a small data room, I noticed that redundant power supplies of a server are connected through a C14 splitter which, in turn, is connected to a single socket of a UPS.
I told the ...
0
votes
2
answers
3k
views
Power Supply Information
Is it possible to view power supply information of a remote Windows (2008) server? It's a Dell Poweredge R720
The physical server is in a remote location and I only have RDP access. I can't see ...
-1
votes
2
answers
84
views
Random shutdown, then doesn't power-on until power-plug is pulled out from wall and plugged back in [closed]
We have a workstation machine which, for the past three days, shuts down (apparently) randomly. After it shuts down, if you press the power button, the machine won't start. However, if you pull out ...
3
votes
4
answers
16k
views
Why do servers have 2 PSU?
I have a Dell PowerEdge 2900 server and it has 2 PSUs, so: Can I run the server by having only one PSU plugged in?
I am not going to have this server on all day and night. I'm just using it to learn ...
-1
votes
1
answer
402
views
HP DL360 G5. Doesn't start if power cable plugged in PSU1
I bought an used server. When I plugged in a first PSU (the one near sidewall) a power cable, some fans turned on, a led on the front panel light orange, on mobo green leds works. When I press a power ...
-1
votes
2
answers
53
views
Power server when power is on (No Bios access)
I have 3 servers and one is old hardware. I have frequent power outage due a Kw limit.
I know there is an option in the BIOS to power on a machine when there is power.
2 servers does have this AC ...
2
votes
3
answers
747
views
Safely conduct tests that require unplugging server
So, basically I am testing and diagnosing my UPS's as well as the power sources (PSU) of my server. For that purpose I am powering down the server "the hard way", by unplugging it from the wall as to ...
1
vote
1
answer
529
views
HP DL180g6 requires operator intervention to boot on one power supply
Summary: Used DL180g6, with redundant power supplies, that just came in will not boot unless either both supplies are powered or the operator presses F1 on the keyboard. If 2nd supply comes up after ...
4
votes
1
answer
6k
views
HP Proliant DL380 G7 power calculation
HP Proliant DL380 G7 in year of production has alternative PSU:
750W in "performance" configurations with 2 CPU
460W in "base" and "entry" with 1 CPU
"Power advisor" calculator is not accesible in ...
1
vote
1
answer
329
views
Sun Fire v440 does not power on
I have an old Sun Fire v440 server which was in working condition before a shutdown a few months ago.
Today I tried to power it on but nothing happens when I press the power button.
On both PSUs ...
-3
votes
1
answer
50
views
Loud Pop from DL380G5--then neither PSU lights up when plugged in
I wanted to fire up my old DL380 G5 server recently, and maybe one second after I hit the power button and the fans started to rev up, I heard a loud pop and suddenly it shut down. Now neither PSU ...
4
votes
2
answers
2k
views
Redundant UPS with 2 power sources
I've 2 power sources in my house: One from the national power grid and another from an internal power source. I've several power sockets in my server room from these 2 sources.
Did some research and ...
5
votes
1
answer
6k
views
Is it possible to convert 4-pin floppy to SATA power?
I just bought a server and realized that it had power for all my drive bays, but not for the internal SSD I bought for it. It does, however, have 2 free 4-pin floppy power connectors:
Is it possible ...
-1
votes
1
answer
280
views
600W PSU max Watt load [closed]
I have purchased an EVGA 600W Silver PSU.
It is connected to the following: Motherboard + CPU + SSD + 3 x Video Card (RX 470 with riser cables).
I have a watt meter which I have connected to the PSU ...
5
votes
1
answer
4k
views
spontaneous reboot, machine check events, AMD ryzen [closed]
I've been running a brand new system on arch linux for about 3 weeks, and last night it spontaneously rebooted.
There's no shutdown/halt in journalctl at the time of the reboot, so I'm pretty sure ...
0
votes
1
answer
1k
views
Power Led Error in IBM/Lenovo M5 X3100 Server
I have a x3100 M5 Lenovo/IBM machine that is being used as file server. As of yesterday it had two 2.5" Samsung SSD's plugged in. Today I tried plugging in 2 x 3.5in 4TB hard drives, and when I tried ...
1
vote
2
answers
377
views
HP Proliant DL160 No Power Meters detected?
I've recently installed the hpasmcli on my ProLiant DL160 G6 and wanted to see what kind of power draw it was having. However, when I try to use the show powermeter command, I get a "no power meters ...
-1
votes
1
answer
96
views
Halt, not power down, a windows server
A client recently changed their UPS and now claims that their server is not coming back up after am extended power outage. They have tested their system and it will keep the last state, so if the ...
3
votes
2
answers
4k
views
HP ProLiant server - PSU error despite replacing PSUs
We have a HP ProLiant ML350 G6 server causing us a few problems.
The main symptom was that every so often we would find the server simply powered off. We turned the machine back on and investigated ...
9
votes
4
answers
684
views
Redundant Power Supply Sloshing (If sloshing is the right word)
I have a Supermicro Redundant Power Supply with two units in it. I also have two UPS units, one for each of the Power Supplys. I was watching the LCD on the UPSs for the watt usage. The total watts ...